sieve analysis-sand , particle size analysis-procedure, sieve analysis-fine aggregate


particle size analysis


SCOPE: 

To determine the particle size distribution of fine aggregates by sieving as per IS Code.

 IS CODE: IS: 2386 (Part I) - 1963. 






APPARATUS: 

1. A set of IS Sieves of sizes - 4.75mm, 2.36mm, 1.18mm, 600micron,300micron, 150micron and 75micron. 
2. Balance or scale with an accuracy to measure 0.1 percent of the weight of the test sample



 PROCEDURE:


 1. The test sample is dried to a constant weight at a room temperature of 110 + 5 C and weight. 

2. The air- dry sample shall be weighed and sieves successively on the appropriate sieves starting with the largest. 

3. Before using the sieves it should be cleaned.

 4. Take 1000 grams of fine aggregate, it should be shaken for a period of not less than 2 minutes. 

5. Lumps of fine particles, if present may be broken by gentle pressure of fingers against the side of sieve.

 6. Light brushing with a soft brush on the underside of the sieve may be used clear the sieve opening.

 7. On completing the sieving, the material retained on each sieve, shall be weighed. 

8.The cumulative weight passing each sieve shall be calculated as a percentage of the total sample weight. 


SPECIFICATIONS:

 IS SIEVE DESIGNATION ✓

 % PASSING 
 4.75MM. √ 90 - 100
 2.36MM. √ 75 - 100 
1.18MM. √ 55 - 90 
600 MICRON √ 35 - 59 
300 MICRON √ 8 - 30 
150 MICRON √ 0 - 10 




Post a Comment

Previous Post Next Post