particle size analysis
SCOPE:
To determine the particle size distribution of fine aggregates by sieving as per IS Code.
IS CODE: IS: 2386 (Part I) - 1963.
APPARATUS:
1. A set of IS Sieves of sizes - 4.75mm, 2.36mm, 1.18mm, 600micron,300micron, 150micron and 75micron.
2. Balance or scale with an accuracy to measure 0.1 percent of the weight of the test sample
PROCEDURE:
2. The air- dry sample shall be weighed and sieves successively on the appropriate sieves starting with the largest.
7. On completing the sieving, the material retained on each sieve, shall be weighed.
8.The cumulative weight passing each sieve shall be calculated as a percentage of the total sample weight.
SPECIFICATIONS:
IS SIEVE DESIGNATION ✓
% PASSING
4.75MM. √ 90 - 100
2.36MM. √ 75 - 100
1.18MM. √ 55 - 90
600 MICRON √ 35 - 59
300 MICRON √ 8 - 30
150 MICRON √ 0 - 10
Tags: